Sep 12, 2019· The type of pneumatic actuator is scotch and yoke due to quarter turn functionality of the ball valve. The second step is to calculate the maximum torque required to open the valve at maximum pressure differential (the breakaway torque) [4, 5]. A practical way to calculate the amount of torque is to multiply the force by the lever arm.

With variable torque actuators the required valve torque across the valve stroke must be examined. At the beginning of each stroke the valve torque is the is called the break torque,which are the torques outlined on the charts found on pages 27 and the ball is turned the torque

Jun 23, 2020· Rotary (QuarterTurn) Operation – This includes plug valves, ball valves, and butterfly valves. Quarterturn dampers would also fall into this category. These types of valves are generally easier to fit with the appropriate actuator as the operation is relatively simple, requiring a 90degree rotation at the appropriate torque.

Break torque, or opening torque, refers to the force required to start moving a closed valve. Running torque, or midstroke torque, is the force required to maintain movement of the valve between the open and closed positions. Seating torque, also called closing torque, is the force required to seat a valve into its closed position.

This paper presents a case study of breakaway torque (break to open) calculation and actuator sizing for a fullbore ball valve in pressure Class 300 equal to 50 barg nominal pressure and 22Cr ...

Sanitary Valves. 2Way Ball Valves; 3, 4, 5Way MultiPort Valves; 3Way Diverter Port Valves; Check Valves (Poppet Type) Clean Steam Ball Valves ... 8 weeks? Some of our kits can be shipped same day if required! Jeff Kerr. PBM, Engineering Manager. PBM''s engineering and manufacturing teams will work with you to design your special valve ...

Valve torque is also a function of the media flowing through the valves . Abrasive media have a tendency to increase the amount of friction between the ball and seats, whereas some light oils, which provide additional lubricity, can reduce the amount of torque required . The torque required to operate a ball valve is maximum at the begin

Apr 09, 2019· End to close (ETC) The torque required to fully close the valve when the valve is about to close. 6. BTO with double block This torque is measured when the valve is closed and the ball opens against both seats under pressure. Figure 8 shows the position of the ball in different torque conditions.

valve disc. Ball and plug valve do not see significant stem loads caused by flow or pressure. For these valve designs, the required valve stem torque is simply the bearing load. Butterfly valves have complicated disc torque loads due to the flow over the disc at various angles of stem rotation. Gate/Globe Valve Stem Torque Stem Factor ...

Maximum allowable stem torque/thrust (MAST) is defined as the maximum torque/thrust that can be applied to the valve train without risk of damage, as defined by the valve manufacturer/supplier.

Sep 03, 2020· For positionseated valves the torque switch can still be used, but as overtorque protection in case there is an obstruction in the line. A torqueseated valve (, gate valve) will use the torque switches to properly seat the valve at the required torque setting.

Ball Valve Torques: The torque values listed in the following tables are breakaway torques from the closed position. Breakaway torques are determined by measured after the valve has been in the closed position under pressure for a set time period, and are the highest torques expected.

To order the JAMESBURY ball valves equipped with TORQHANDLE springreturn handles,specify either TORQHANDLE A or TORQHANDLE B (s ee Torque Output Table) after the valve figure number,for example,1/2" TT with TORQHANDLE A. VALVE CENTER LINE Approximate Dimensions "ELIMINATOR™ MOD. B"– inches (mm) Valve Size inches DN M

TQCL TORQUE FOR WP1 TQCW = TORQUE FOR CWP (MAX CWP) TQST = TORQUE FOR STP Note: Kgfm = Nm Note: This table is a general guide only, all figures can vary depending on trim, bonnet type, disc/wedge type, handwheel size, packing and other factors. It should be used for estimation purposes only as specifications can and do change.

Jun 15, 2015· Severe service ball valve manufacturer, MOGAS Industries, is studying the impact of dynamic torque and its affect on accurate actuator sizing. At the MOGAS RD facility, modified dynamic torque calculations are being developed to best understand the impact it has on flow conditions, pressure drops, flow rate and torque outcome.

A ball valve consists of a valve body in which a large sphere with a central hole equal to the inside diameter of the pipe is mounted. As the ball is rotated, in the fully open position the valve provides the through conduit or full bore required for unrestricted flow of the fluid and scrapers or pigs.

Ball Valve Torque Calculation Formula ... Seating torque, also called closing torque, is the force required to seat a valve into its closed position. Maximum shaft torque or Maximum Allowable Stem Torque (MAST) is the most force that can be applied to a stem valve before deformation occurs. Different valve types have ...

Jan 02, 2015· Break torque usually defines the size of the gear and is the highest torque value, followed by seating torque. Run torque, the torque required while the valve is cycling, usually is the lowest torque value and is the torque used for the majority of the valve''s operation. Knowing your application and safety standards is key to gear selection.

The run torque is approximately 50%, or onehalf, of the breakaway torque. The reseat torque is approximately 75%, or threequarters, of the breakaway torque. Corrosion, scale, buildup on the ball, or other service conditions can drastically alter torque requirements and should be given consideration when selecting actuation or automation ...

VALVE/ ACTUATOR TORQUE SIZING ANALYSIS CHART FOR TRUNNION BALL VALVES PISTON STYLE SCOTCH YOKE ACTUATOR SIZING CALCULATIONS SHEET LARGER ACTUATORS 2500Nm TO 17000Nm SPRING RETURN (SET SPRING TO CLOSE) *1 PTFE/RPTFE seats can require more torque to unseat after a period of time due to its fluidity memory.

exposed to thrust or torque exceeding these stress limits. NOTE Typical quarterturn valvetoactuator interfaces are given in ISO 5211. The manufacturer shall state the maximum permissible input torque or thrust for the valve operator. If specified by the purchaser, valves shall be provided with a pressure cap.

b) Ball valve with solid circular stem rectangular crosssection at the end of stem for connection to ball(Type B) (Valve / Actuator mounting bracket design ISO 5211 and stress calculation Not covered in this presentation). c) This guide is applicable to trunnion mounted ball valves only. d) This guide is limited to maximum allowed torque ...

alignment may increase required torque. Because of the nature of synthetic seal materials used in ball valves, the torque values are not constant. Conditions such as pressure, temperature, type of fluid, amount and kind of suspended material in the fluid, and frequency of operation all affect the torque .

2. Formulas used to calculate values of below mentioned torques based on BTO value: TORQUE FORMULA VALVE CLASS RUN (Running Torque) x BTO All ETO (End To Open) x BTO All BTC (Break To Close) x BTO All ETC (End To Close) x BTO All Document No.: D/BAL017EA Torque Values for SD Series Product Data Sheet uly 2016